Hermetic package design on a ceramic substrate centers on three variables: the ceramic body material, the seal metallurgy, and the CTE match between every joined surface. A properly designed hermetic ceramic package keeps moisture, oxygen, and contaminants below levels that would degrade the enclosed device over its service life. The defining metric is helium fine-leak rate, typically specified at or below 1 × 10⁻⁸ atm·cc/s per MIL-STD-883 Method 1014. Get any one of those three variables wrong, and the seal will crack during thermal cycling or fail gross-leak screening on the production floor.

The word “hermetic” has a specific meaning in electronics packaging: the enclosure must prevent ingress of moisture vapor at a rate low enough that the internal dew point stays below −40 °C for the rated service life—typically 20 years for space or implantable medical devices. Per MIL-STD-883 Method 1014, packages are tested with helium fine-leak and fluorocarbon gross-leak methods. A fine-leak rate below 1 × 10⁻⁸ atm·cc/s (for cavity volumes under 0.4 cm³) is the standard pass criterion.
Ceramic bodies are inherently gas-tight in their bulk form. Leaks occur at joints: lid-to-frame seals, feedthrough pins, plated through-holes in the ceramic substrate, and metallised seal rings. Hermetic package design is therefore primarily seal-joint design.
| Material | CTE (ppm/°C, 20–300 °C) | Thermal Conductivity (W/m·K, 25 °C) | Flexural Strength (MPa) | Typical Use | Source |
|---|---|---|---|---|---|
| Al₂O₃ 92 % | 6.5–7.2 | 18–22 | 320–350 | Standard IC, sensor packages | CoorsTek ADS-92 |
| Al₂O₃ 96 % | 6.7–7.4 | 24–28 | 340–380 | RF, military hybrids | Kyocera A-476 |
| AlN | 4.4–4.7 | 170–200 | 300–350 | High-power laser, IGBT | Maruwa AN-200 |
| LTCC (various) | 5.0–7.0 | 2–4 | 200–250 | Multilayer RF, MEMS | DuPont 951 |
Typical values for commercially available material, for comparison only. Confirm against the datasheet for your specific grade.
Al₂O₃ 92–96 % dominates because its CTE (6.5–7.4 ppm/°C) is a close match to Kovar (5.1–5.5 ppm/°C) and Alloy 42 (4.3–5.6 ppm/°C), the two most common seal-frame and lead-frame metals. AlN’s lower CTE (4.4–4.7 ppm/°C) pairs better with silicon dies and GaN devices but requires more care in frame alloy selection. For laser diode submount designs, AlN is often the only viable choice because the die must stay below 60 °C during CW operation.
| Parameter | Solder/Braze (AuSn, AuGe) | Seam Weld | Glass Frit |
|---|---|---|---|
| Seal temperature | 280–360 °C | ~1 000 °C local, package stays < 150 °C | 350–450 °C |
| Typical leak rate achieved | < 1 × 10⁻⁹ atm·cc/s | < 5 × 10⁻¹⁰ atm·cc/s | < 1 × 10⁻⁸ atm·cc/s |
| Reworkable? | Yes (reflow) | No | Limited (one refire) |
| Atmosphere control | N₂ or vacuum furnace | Glove box or chamber welder | Belt furnace, N₂ |
| Cost per seal (relative) | High (Au preforms) | Medium (capital equipment) | Low |
Values representative of production practice; actual results depend on geometry, metallisation quality, and process control.
80Au/20Sn (eutectic at 280 °C) is the workhorse for optoelectronic and military packages. The seal ring on the ceramic is typically sputtered or plated Ti/Ni/Au or W/Ni/Au. The lid carries a matching metallisation or a preform ring. Reflow occurs in a N₂ or forming-gas atmosphere. AuSn wets aggressively and fills gaps up to ~25 µm, making it forgiving of minor flatness deviations. The downside is material cost: a 10 × 10 mm AuSn preform ring (0.05 mm thick) contains roughly 0.04 g of gold.
Two copper-alloy roller electrodes pass current through a Kovar lid flange, fusing it to a Kovar seal ring brazed to the ceramic body. Peak temperature at the weld zone exceeds 1 000 °C, but the thermal mass of the ceramic keeps the cavity below 150 °C—critical for temperature-sensitive MEMS or IR detectors. Seam welding produces the tightest seals in production (routinely < 5 × 10⁻¹⁰ atm·cc/s) and is the default for MIL-qualified packages. It requires a Kovar or Alloy-42 frame; all-ceramic lids cannot be seam-welded.
A lead-free or lead-bearing glass paste is screen-printed on the seal surface, dried, and fired at 350–450 °C. Glass-frit sealing is the lowest-cost option and works well for MEMS accelerometers and pressure sensors. It is less reliable under aggressive thermal cycling because the glass itself is brittle and CTE-sensitive. For high-reliability applications, frit seals are often backed by a secondary epoxy overcoat for mechanical protection—though the epoxy itself is not hermetic.
Enter your substrate dimensions, lid material, and temperature range below to see how CTE mismatch and seal-edge strain change with package size.
Consider a 12 × 12 mm Al₂O₃ 96 % package with a Kovar lid. The CTE of 96 % alumina is ~7.1 ppm/°C; Kovar is ~5.3 ppm/°C. Over a ΔT of 180 °C (−55 °C to +125 °C), the differential strain along the 12 mm seal edge is:
ΔL = L × ΔCTE × ΔT = 12 mm × (7.1 − 5.3) × 10⁻⁶ /°C × 180 °C = 0.0039 mm ≈ 3.9 µm
A 3.9 µm shear displacement per cycle is within the fatigue tolerance of an AuSn solder joint (which can accommodate ~10–15 µm of plastic strain before crack initiation, per Indium Corporation’s AuSn fatigue data). But scale the package to 25 × 25 mm and the displacement doubles to ~8.1 µm—still survivable, but now the safety margin is thin. Above ~30 mm edge length with this CTE mismatch, consider switching to an AlN body (CTE 4.5 ppm/°C, closer to Kovar) or using a compliant seal alloy like In-based solder.
For designs where tolerance stack-up on ceramic substrates is tight, the dimensional change from CTE mismatch must be added to your mechanical tolerance budget.

The ceramic body itself does not leak. Leak paths form at:
Designing feedthroughs for high-voltage ceramic PCB applications adds another constraint: creepage and clearance distances across the glass seal must meet IEC 60664-1 requirements for the working voltage.
Hermetic ceramic packages cost 5–50× more than plastic-moulded alternatives (QFN, BGA). They add weight, extend lead times, and limit package size. Do not specify hermetic ceramic if:
For wire bonding on ceramic substrates, confirm that the seal process temperature will not degrade existing wire bonds—especially if using aluminum wedge bonds, which oxidise above 300 °C in non-inert atmospheres.
No. Epoxy has a moisture-vapor transmission rate orders of magnitude higher than metal or glass seals. It can provide environmental protection for years in benign conditions, but it does not meet the < 1 × 10⁻⁸ atm·cc/s leak-rate threshold defined by MIL-STD-883 for hermetic enclosures.
Production packages with seam-welded or brazed seals are commonly made up to about 50 × 50 mm. Beyond that, CTE-mismatch stress at the seal perimeter grows linearly with edge length, and the risk of seal cracking during thermal cycling increases sharply. Larger assemblies typically use a metal housing with hermetic ceramic feedthroughs instead.
Yes. AlN reacts with many fluxes and plating chemistries. The standard approach is sputtered TiW/Ni/Au or Ti/Pt/Au. Thick-film tungsten paste (common on alumina HTCC) does not adhere well to AlN without a modified firing profile. Always confirm metallisation compatibility with your substrate supplier.
The standard sequence per MIL-STD-883 Method 1014 is: (1) bomb the sealed package in helium at 2–5 atm for 2–16 hours, (2) measure helium leak rate with a mass-spectrometer leak detector, (3) if the package passes fine-leak, perform a fluorocarbon gross-leak test to catch large defects. Both tests are non-destructive.
Yes. LTCC (low-temperature co-fired ceramic) can achieve hermetic seals when the via fills and seal-ring metallisation are properly designed. LTCC is especially useful for RF ceramic PCB designs that need embedded passives and controlled-impedance lines inside a hermetic cavity. Leak rates below 1 × 10⁻⁸ atm·cc/s are routinely achieved with co-fired silver or gold seal rings.
If you are specifying a hermetic ceramic package, start by defining the leak-rate requirement, the thermal cycle profile, and the maximum die temperature. Review the ceramic PCB design rules and DFM guidelines to confirm your substrate layout is compatible with the seal method you have chosen. When you are ready for a quote on hermetic ceramic substrates or packages, submit your files through the AluminaPCB quote page for engineering review.