Locate the optical facet from the same datum used by the mechanical mount. The assembly must meet the specified facet position after die-placement and edge tolerances accumulate.

Identify the emitting facet, die orientation and optical axis on the assembly drawing. Locate the facet or die edge relative to the submount datum. Give the allowable attach fillet on the optical side separately.

For a target positive inset, subtract the worst independent positioning and edge-location errors toward the edge. A negative result indicates possible overhang. Verify against the optical design, including height and tilt.