A ceramic PCB stackup defines the number of conductive layers, the dielectric material between them, the via interconnect strategy, and the metallization method—all of which are constrained by the ceramic process used (DPC, DBC, HTCC, or LTCC). Unlike FR-4, where you laminate prepreg and core in almost any combination, ceramic stackups are limited by co-firing shrinkage, bonding physics, and the brittle nature of the substrate. Getting the stackup right early prevents costly redesigns later.

In FR-4 fabrication, a stackup is built by laminating alternating layers of copper foil and prepreg around a rigid core. You can specify 2, 4, 6, 8, or more layers with standard processes. Ceramic substrates do not work this way. The dielectric is a rigid, pre-sintered or co-fired ceramic sheet—not a resin-impregnated glass cloth. You cannot press additional layers onto it after firing.
This means the stackup is determined at the green-tape or substrate level, before metallization. For DBC (direct bond copper) and DPC (direct plated copper), the substrate is already sintered. You bond or deposit metal on one or both faces. That gives you one or two conductor layers per substrate, period. For multilayer builds, LTCC (low-temperature co-fired ceramic) or HTCC (high-temperature co-fired ceramic) tapes are screen-printed with conductor paste, punched with vias, stacked, and co-fired as a monolithic block. This is a fundamentally different manufacturing sequence, and it governs every stackup decision.
| Process | Max Conductor Layers | Via Types | Typical Dielectric | Use Case |
|---|---|---|---|---|
| DBC | 2 (top + bottom) | None (or drilled mechanical) | Al₂O₃, AlN, Si₃N₄ | Power modules, IGBT substrates |
| DPC (thin film) | 2 (top + bottom) | Laser-drilled, plated through | Al₂O₃ 96%/99.6%, AlN | LED, RF, sensors |
| LTCC | 50+ | Buried, blind, through | LTCC tape (εr 5.8–9.8) | RF filters, 5G modules, aerospace |
| HTCC | 20+ | Buried, blind, through | Al₂O₃ 92–96% | Hermetic packages, mil-spec |
Typical values for commercially available processes, for comparison only. Confirm against the datasheet for your specific grade and supplier.
If your design needs three or more interconnected conductor layers with buried vias, LTCC is almost always the correct choice among ceramic options. HTCC can achieve similar layer counts but requires tungsten or moly-manganese conductors (fired at 1,500–1,800 °C), which have higher resistivity than LTCC’s silver or gold conductors (fired at 850–900 °C). For a deeper look at how vias are formed in each process, see the guide on via design for ceramic substrates.
The majority of ceramic PCBs in production are single-layer (metal on one face) or double-sided (metal on both faces of one substrate). These are the simplest and least expensive ceramic stackups. A typical double-sided DPC board on 0.635 mm Al₂O₃ 96% might look like this:
Through-vias connect top and bottom layers. Laser drilling produces via diameters down to 80–150 µm in DPC. DBC boards typically lack vias; if vertical interconnect is needed, designers use edge castellations or wire bonds instead.
For power electronics, a DBC stackup on AlN (170–200 W/mK thermal conductivity) uses 0.3 mm copper directly bonded to both faces of a 0.635 mm AlN substrate. This three-layer sandwich is the standard building block for IGBT module substrates. No internal routing exists; all interconnect is on the surface or via wire bonds.
LTCC is where ceramic stackup design becomes genuinely complex. Each layer starts as a flexible green tape (typically 50–250 µm thick after firing). The designer specifies conductor patterns on each tape, via locations punched through the tape, and the stacking sequence. After lamination and co-firing at 850–900 °C, the result is a monolithic ceramic block with fully embedded 3D interconnect.
Consider a 5G band-pass filter module operating at 3.5 GHz. The stackup might be:
For a stripline on Layer 3, the impedance depends on the dielectric constant of the LTCC tape (εr ≈ 7.1 for DuPont 951, per the DuPont GreenTape™ 951 datasheet), the trace width, and the distance to the adjacent ground planes. With two 100 µm fired tape layers above and below (total ground-plane spacing 200 µm) and εr = 7.1, a 50 Ω stripline requires a trace width of roughly 85–95 µm. This is significantly narrower than the same impedance on FR-4 (εr ≈ 4.3), which would need approximately 130–140 µm at the same ground spacing.
This kind of stackup is standard in 5G infrastructure ceramic modules and RF ceramic PCB designs where size, loss, and hermeticity matter.
[pcb_calc type=”stackup-recommend”]

LTCC tapes shrink 12–16% in X-Y and 15–25% in Z during co-firing (values per DuPont 951 and Ferro A6M datasheets). This shrinkage must be compensated in the artwork. Layer-to-layer misregistration after firing is typically ±25–50 µm, which sets the minimum annular ring and via-to-trace clearance. Some zero-shrinkage LTCC processes (e.g., Heraeus CT700 series) constrain X-Y shrinkage to < 0.1% using sacrificial tapes, improving registration to ±15 µm. For tolerance analysis across multiple ceramic layers, the principles in ceramic tolerance stack-up analysis apply directly.
LTCC vias are punched in green tape and filled with conductor paste before stacking. Minimum via diameter is typically 100–150 µm (fired). Stacked vias (directly aligned through multiple layers) are standard in LTCC and preferred for thermal and RF grounding. Staggered vias require more routing space but reduce stress concentration at via columns. Via pitch is limited by the punching tool and paste bleeding; 250–300 µm center-to-center is a practical minimum for most LTCC foundries.
Screen-printed Ag on LTCC fires to 8–15 µm. Sheet resistance is 2–5 mΩ/square—higher than etched copper on FR-4 (≈ 0.5 mΩ/square for 35 µm Cu). This matters for DC power distribution and high-current paths. If low resistance is critical, increase trace width or use copper-filled vias where the LTCC system supports it.
| Parameter | Al₂O₃ 96% (DPC/DBC) | AlN (DBC) | LTCC (DuPont 951) | Unit | Source |
|---|---|---|---|---|---|
| Dielectric constant (1 MHz) | 9.0–9.8 | 8.5–9.0 | 7.1 ± 0.2 | — | Kyocera A-493 / DuPont 951 datasheet |
| Loss tangent (1 MHz) | 0.0001–0.0004 | 0.0003–0.001 | 0.0015 | — | Same |
| Thermal conductivity | 24–28 | 170–200 | 3–4.4 | W/mK | Same |
| CTE (20–300 °C) | 7.0–7.5 | 4.5–5.0 | 5.8–6.5 | ppm/°C | Same |
| Flexural strength | 300–380 | 300–400 | 200–320 | MPa | ASTM C1161 |
Typical values for commercially available material, for comparison only. Confirm against the datasheet for your specific grade.
The lower thermal conductivity of LTCC (3–4.4 W/mK) is its main weakness in power applications. Thermal vias help, but a 6-layer LTCC stackup will never match a single-layer DBC on AlN for heat extraction. Choose the stackup complexity your interconnect requires, and pair it with the thermal path your power budget demands. In some designs, an LTCC multilayer sits on top of a DBC power substrate, combining routing density with thermal performance.
Ceramic stackups are the wrong choice in several common scenarios:
For general ceramic PCB design guidelines, start with the substrate and process selection before committing to a stackup.
Yes, but with constraints. Some LTCC systems allow mixing tapes with different dielectric constants (e.g., a high-εr layer for embedded capacitors next to a low-εr layer for transmission lines). The tapes must have matched shrinkage rates and firing profiles. Not all foundries support this; confirm with your manufacturer before designing it in.
LTCC routinely produces 10–30 layer stackups and can exceed 50 layers for specialized modules. HTCC typically reaches 20+ layers. DBC and DPC are limited to 2 conductor layers per substrate without mechanical stacking.
For RF and mixed-signal designs, yes—ground planes between signal layers control impedance and reduce crosstalk, just as in FR-4. For pure DC power routing or simple sensor substrates, you can omit intermediate ground planes and save layers, but you lose shielding.
LTCC green tapes are available as thin as 25–50 µm (fired thickness). DuPont 951 is available in 42 µm fired thickness. Thinner dielectrics enable tighter coupling for embedded capacitors and smaller overall stackup height, but they reduce mechanical strength and increase the risk of via-to-via shorting.
Not by co-firing. Post-fire options include thin-film deposition (sputtering additional metal layers with polyimide or SiO₂ dielectric) or bonding a second fired substrate on top with solder or epoxy. Both add cost and process steps. Plan your layer count before firing.
Define your layer count, dielectric material, and via strategy before requesting a quote. If your design needs more than two conductor layers, specify whether LTCC or HTCC is acceptable and provide your impedance and thermal targets. Upload your stackup and Gerber files for a ceramic PCB design review and quote.